Contents
MIMcCall IntertradeMI

Home › Articles

Checklist for Evaluating Medical Suppliers at Trade Shows

By David McCall · Published · 5 minutes read

Clipboard with a supplier evaluation checklist and pen.
Clipboard with a supplier evaluation checklist and pen. · Foto: athree23 / Pixabay

A medical trade show floor compresses weeks of supplier due diligence into two or three days. You will meet more potential partners in an afternoon than your team might otherwise screen in a quarter, but each conversation is short and almost every supplier is on its best behaviour. The difference between a useful trip and an expensive one is having a consistent framework you apply to every booth, so that the notes you carry home are comparable rather than a stack of glossy brochures.

The checklist below is the one we use when supporting procurement teams at events such as Medica and Pharmapack. It covers the questions worth asking in person, the documents to request before you leave the hall, and the red flags that rarely appear on a supplier's own presentation. Treat it as a screening tool, not a final audit: its job is to tell you which five suppliers deserve a factory visit and which twenty can be politely set aside.

Start With Regulatory Status and Scope

Before discussing price, establish what the supplier is actually certified to do. For finished devices, ask for the current ISO 13485 certificate and check the scope statement against the specific product family you need; a certificate covering surgical instruments does not automatically extend to sterile packaging. For components and materials, ISO 13485 may not apply, but ISO 9001, ISO 14001, or IATF 16949 often do, and the scope wording matters as much as the certificate itself.

Ask directly which markets the supplier currently ships to and under which regulatory routes. A contract manufacturer with a live 510(k) or an EU MDR technical file for a comparable device has already absorbed the cost of conformity assessment, which is a meaningful signal. Ask when the last notified body or FDA audit took place and request the outcome summary. Suppliers who answer precisely and without hesitation are usually telling the truth; vague answers about 'all certifications' are worth noting.

  • Certificate number, issuing body, expiry date, and exact scope wording
  • Markets served and regulatory routes (MDR, FDA 510(k), Health Canada, TGA)
  • Date and result of the most recent notified body or FDA audit
  • Named regulatory contact who can answer follow-up questions

Test Manufacturing Capacity and Flexibility

Trade show conversations tend to focus on the sample on the bench, not the factory behind it. Ask how many production lines run the relevant process, what the current utilisation is, and what share of capacity your programme would represent. A supplier running at 85% utilisation across three lines has less room to absorb your ramp than one at 60% across five, even if the unit price looks similar. Ask what happens to lead times when their largest customer doubles an order.

For medical work, also probe how they handle change control and process validation. A supplier that can describe its IQ/OQ/PQ approach and its change notification window in plain terms is likely to be a workable partner. Ask how long a tooling change or a material substitution takes to move through their system, and whether you would be notified before or after the change is made. The answer tells you a great deal about how the relationship will feel in year three.

  • Number of lines, shifts per week, and current utilisation
  • Typical and peak lead times, plus the trigger for each
  • Change notification window in the quality agreement
  • Approach to IQ/OQ/PQ and revalidation triggers
30Quality system25Regulatory scope20Capacity15Commercial terms10Logistics
Weighted importance of supplier criteria in trade show screening (Weight (%))

Commercial Terms: MOQs, Pricing, and Payment

Ask for minimum order quantities at three volumes: prototype, pilot, and serial production. A supplier quoting an MOQ of 10,000 units for a device you expect to sell 2,000 of in year one is either the wrong partner or is signalling that it wants a different kind of customer. Clarify whether the MOQ applies per part number, per order, or per year, and whether it changes once tooling is amortised. Get the pricing ladder in writing, including the volume bands.

Payment terms and currency exposure deserve ten minutes of the meeting. Standard terms in European medical contract manufacturing sit around 30 to 60 days net, but first orders often require a deposit of 30 to 50%. Ask who bears tooling cost, when it is invoiced, and whether it is refundable against future volume. If the supplier quotes in a currency other than yours, ask how they handle exchange rate movement on multi-year agreements.

  • MOQ at prototype, pilot, and serial volume, and the basis for each
  • Price bands by volume, with tooling and NRE listed separately
  • Payment terms, deposit percentage, and currency clause
  • Validity period of the quotation (typically 30 to 90 days)
Supplier screening criteria and typical benchmarks at medical trade shows
CriterionWhat to ask forTypical acceptable rangeRed flag
Quality certificationISO 13485 certificate with scopeCurrent, scope matches productExpired or scope mismatch
Audit historyLast notified body or FDA outcomeWithin 24 months, no major NCRefuses to share outcome
Lead timeQuoted serial production lead time8–16 weeks for devicesUnder 4 weeks without explanation
MOQMOQ at pilot and serial volumeFlexible at pilot stageSix-figure MOQ for new programme
Payment termsStandard terms and deposit30–60 days net, 30–50% deposit100% prepayment on first order
Record retentionDevice history record retention10+ years after last shipmentFive years or unspecified

Quality Systems and Traceability in Practice

Every supplier will claim a robust quality system. Move the conversation to specifics: how are lots traced from raw material to finished device, what is the retention period for device history records, and how quickly can they retrieve a record for a lot shipped two years ago? Under MDR, technical documentation must be retained for at least ten years after the last device is placed on the market, so a supplier with a five-year retention policy is a problem you will inherit.

Ask about non-conformance handling and the metrics they actually track. A supplier who can quote a recent internal scrap rate, an on-time delivery figure, and a CAPA closure time is managing the process. One who cannot is hoping you will not ask. Ask how they handle complaints originating from your customers and what the typical response time is. If the answer involves a shared portal and a named quality engineer, that is a good sign.

  • Lot traceability method and record retention period
  • Recent internal scrap rate and on-time delivery figure
  • CAPA closure time and complaint response window
  • Willingness to accept your audit or a third-party audit

Logistics, Packaging, and Sterile Barrier Systems

If your product ships sterile, the packaging conversation belongs in the first meeting, not the last. Ask who designs and validates the sterile barrier system, which standards they work to (typically ISO 11607-1 and -2), and whether they have in-house accelerated ageing and seal strength testing. Suppliers who outsource sterilisation should be able to name the facility and describe the transit route between manufacturing and the steriliser, because that leg is where many validation assumptions quietly break.

For non-sterile components, ask about packaging formats, pallet configurations, and Incoterms. A supplier quoting EXW when you assumed DDP changes the landed cost materially. Ask what their typical shipment size is, whether they consolidate, and how they handle expedited freight. If you are comparing several suppliers across a show, it helps to keep the logistics picture consistent with how you compare trade show logistics providers for medical events so that freight assumptions do not distort the comparison.

The Questions That Reveal the Real Relationship

Some of the most useful information comes from questions that are slightly off-script. Ask who their longest-standing medical customer is and how long the relationship has run. Ask what went wrong in the last twelve months and what they changed as a result. Ask which part of their operation they would most like to invest in and which they consider a bottleneck. Suppliers who answer these with specifics are usually comfortable with scrutiny, which is exactly the posture you want in a partner.

Finally, ask about the team you would actually work with: who is the account manager, who is the quality contact, and will those people be the same in eighteen months? Staff turnover in contract manufacturing is a real risk, and a supplier with a stable, named team is easier to onboard. Book a follow-up call for two weeks after the show and see how quickly they send the documents you requested. Response speed after the event is often a better predictor than anything said at the booth.

  • Longest-standing medical customer and relationship length
  • A recent failure and the corrective action taken
  • Named account, quality, and regulatory contacts
  • Document pack delivered within an agreed deadline
  • Screen for regulatory scope and audit history before discussing price; a certificate that does not cover your product family is not a qualification.
  • Ask for MOQs at three volumes and a written price ladder, so you can compare suppliers on the same basis after the show.
  • Traceability and record retention are inherited obligations under MDR; confirm ten-year retention in the first meeting.
  • Response speed in the two weeks after the event predicts partnership quality better than anything said at the booth.
David McCall · Editor-in-Chief
David has over a decade of experience in medical trade show strategy and product sourcing. He founded McCall Intertrade to help suppliers and buyers connect effectively. He writes about trade show best practices and industry trends.

Related

↑